Drilling Assay Results Show Promise
Released
Released
Announcement PDF
ASX ANNOUNCEMENT
16 July 2024
Drilling Assay Results Show Promise
• RC drilling assay results show promising results
• Peak 6m composite Li2O results of 303.8ppm
• Fertile lithium-cesium-tantulum pegmatite system confirmed
Bryah Resources Limited (ASX: BYH, “Bryah” or “the Company”) is pleased to announce the assay
results from its reverse circulation drilling (RC) on its Pegasus prospect at the Lake Johnston project.
Commenting on the results, Bryah CEO Ashley Jones said: “The assay results from Pegasus have
confirmed lithium mineralisation in the area that we have drilled, and that we are drilling in a fertile
LCT system. Further assays from 1m intervals through areas of interest will be undertaken and help
to build out the picture of the anomalism that we have found so far.
The Lake Johnston area is highly prospective for lithium, and we will continue the approvals process
to further explore the Sphinx prospect and the Roundbottom prospect where pegmatites are
outcropping.”
Pegasus RC drilling
Following on from soil sampling completed in late 2023 and early 2024 a coherent lithium anomaly
was defined on the area which was then defined as the Pegasus prospect. 1 Further soils were
undertaken, a drill program designed and implemented, and all the necessary government and
heritage approvals given before drilling was undertaken in late April to early May.
24 drill holes were completed for a total of 3487m to test the soil anomalies. Drill holes were
sampled in their entirety in 6-meter composites and then submitted to Intertek Genalysis for a
broad suite of assays including lithium, major and trace elements. Assay results were received and
have been verified and interpreted. Selected intervals will be submitted on the 1m intervals to assist
with the interpretation.
Intervals have been selected for additional sampling which will be undertaken subject to the
condition of exploration tracks as the prospect area and associated access tracks have been the
subject of extensive rains over the last two months.
1
ASX announcement 22/01/2024 First Drill Targets Defined by Soil Anomalies
ASX: BYH | bryah.com.au
1
Table 1: Significant intercepts from 2024 Pegasus RC drill program, down hole depths shown, true widths unknown.
Drill Hole
24LJRC0002
including
24LJRC0006
and
and
24LJRC0007
including
and
24LJRC0011
24LJRC0012
24LJRC0014
24LJRC0016
24LJRC0017
24LJRC0020
and
and
24LJRC0021
24LJRC0023
24LJRC0024
ASX: BYH | bryah.com.au
Interval
From
To
108
120
114
120
12
24
30
36
120
126
102
132
102
108
126
132
18
24
120
126
12
18
48
150
54
60
66
72
120
126
132
138
96
102
12
18
114
120
Intercept
12m @ 289.8ppm Li2O
6m @ 303.8ppm Li2O
12m @ 100.5ppm Li2O
6m @ 102.5ppm Li2O
6m @ 227.8ppm Li2O
30m @ 162.8ppm Li2O
6m @ 289.8ppm Li2O
6m @ 205.8ppm Li2O
6m @ 101.8ppm Li2O
6m @ 105.5ppm Li2O
6m @ 106.8ppm Li2O
102m @ 94.7ppm Li2O
6m @ 109.4ppm Li2O
6m @ 233ppm Li2O
6m @ 217.5 ppm Li2O
6m @ 147.9ppm Li2O
6m @ 94.9ppm Li2O
6m @ 101.2ppm Li2O
6m @ 129.4ppm Li2O
2
Figure 1: Pegasus drilling location map with reinterpreted Li2O gridding of the soil anomally.
ASX: BYH | bryah.com.au
3
Figure 2: Cross section 1 (as shown in figure 1) with Li2O line graph shown
Figure 3 Cross section 2 (as shown in figure 1) with Li2O line graph shown: Lake Johnston Lithium
ASX: BYH | bryah.com.au
4
The Lake Johnston area continues to grow as a prospective lithium corridor with significant
discoveries made by Charger Metal’s (ASX CHR) Medcalf discovery and TG Metal’s Burmeister
project. The Lake Johnston Project consists of nine granted exploration licenses, held by Bryah, and
its 100% owned subsidiary West Coast Minerals Pty Ltd.
For further information, please contact:
Ashley Jones, CEO
+61 8 9321 0001
This announcement has been produced in accordance with the Company's published continuous disclosure policy and
has been approved by the Board.
ASX: BYH | bryah.com.au
5
ABOUT BRYAH RESOURCES
Bryah’s assets are all located in Western Australia, a Tier One global mining and exploration jurisdiction.
Strategically the Projects are energy metals focused, or able to exploit synergies of geological knowledge,
locality and exploration.
The Lake Johnston tenements are prospective for battery metals lithium and nickel. The corridor near Lake
Johnston contains significant mines and discoveries of nickel and lithium, including the historical Maggie
Hays/Emily Ann nickel deposits and the TG Metals Burmeister Project and Charger Metals’ Medcalf
Prospect.
The prospective Bryah Basin licences cover 1,048km2 and have a potential new Volcanogenic Massive
Sulphide (VMS) ‘Horseshoe Lights type’ mine analogue with multiple other untested targets. The area also
contains extensive outcroppings of manganese, the subject of a substantial $7M joint venture with ASX listed
OM Holdings Limited (ASX: OMH). OMH is a vertically integrated manganese producer and refiner with a
market capitalisation of ~$340m. Bryah and OMH have an excellent working relationship, with OMH having
already spent over $3.5 million to earn-in to the Manganese Rights of the Project.
Gabanintha, near Meekatharra, has a JORC 2012 Mineral Resource for Cu, Ni, Co2 and additional structural
gold potential. The copper nickel resource and identified gold mineralisation at Gabanintha will be the subject
of further drill definition and a prefeasibility study to integrate the project with the Australian Vanadium
Project (ASX: AVL). The resource has been defined by the drilling efforts of AVL in the development of its
vanadium project and enabled Bryah to define a base metal resources inventory.
Bryah’s base metals inventory at Gabanintha and manganese JV in the Bryah Basin have a clear pathway to
production.
Bryah holds 11.86% of gold focused Star Minerals (ASX:SMS). Star has a Mineral Resource at Tumblegum
South and exploration prospects in the West Bryah Basin.
Forward Looking Statements
This report may contain certain “forward-looking statements” which may not have been based solely on historical facts,
but rather may be based on the Company’s current expectations about future events and results. Where the Company
expresses or implies an expectation or belief as to future events or results, such expectation or belief is expressed in
good faith and believed to have a reasonable basis. However, forward looking statements are subject to risks,
uncertainties, assumptions and other factors which could cause actual results to differ materially from future results
expressed, projected or implied by such forward-looking statements. Readers should not place undue reliance on
forward looking information. The Company does not undertake any obligation to release publicly any revisions to any
“forward looking statement” to reflect events or circumstances after the date of this report, or to reflect the occurrence
of unanticipated events, except as may be required under applicable securities laws.
COMPETENT PERSON STATEMENT – EXPLORATION RESULTS AND EXPLORATION TARGETS
The information in this announcement that relates to Exploration Results is based on information compiled by Mr Tony
Standish, who is a Member of the Australian Institute of Geoscientists. Mr Standish is a consultant to Bryah Resources
Limited (“the Company”). Tony Standish has sufficient experience which is relevant to the style of mineralisation and
type of deposit under consideration and to the activity which he is undertaking to qualify as a Competent Person as
defined in the 2012 Edition of the ‘Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore
Reserves’. Tony Standish consents to the inclusion in this announcement of the matters based on his information in the
form and context in which it appears.
Where the Company refers to Exploration Results in this announcement (referencing previous releases made to the
ASX), the Company is not aware of any new information or data that materially affects the information included in the
relevant market announcements.
ASX: BYH | bryah.com.au
6
Appendix 1 – Drilling information and assay results
Table 2: Drill collar information for the 2024 Pegasus RC drilling
Hole ID Max
Depth
150
24LJRC0001
150
24LJRC0002
150
24LJRC0003
150
24LJRC0004
150
24LJRC0005
150
24LJRC0006
150
24LJRC0007
123
24LJRC0008
128
24LJRC0009
132
24LJRC0010
141
24LJRC0011
150
24LJRC0012
113
24LJRC0013
150
24LJRC0014
150
24LJRC0015
150
24LJRC0016
150
24LJRC0017
150
24LJRC0018
150
24LJRC0019
150
24LJRC0020
150
24LJRC0021
150
24LJRC0022
150
24LJRC0023
150
24LJRC0024
ASX: BYH | bryah.com.au
Grid ID
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
MGA94_51
Easting Northing Estimated Azimuth
RL
(TN)
305150
304953
304753
305365
305162
304965
304762
305172
304970
304767
305343
305139
300264
300063
299866
303322
303126
305268
305065
304866
304655
305067
304858
304661
6414641
6414644
6414644
6413994
6414005
6414004
6414002
6415284
6415287
6415280
6415928
6415926
6415277
6415277
6415279
6415280
6415280
6414319
6414318
6414316
6414326
6414000
6414003
6414004
300
300
300
300
300
300
300
300
300
300
300
300
295
295
295
310
310
300
300
300
300
295
295
295
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
Dip
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
7
Table 3: Significant Assays above 100ppm Li2O
Hole ID
Depth
From
Depth To
Li2O ppm
Geology
NSA
24LJRC0001
24LJRC0002
114
120
303.8
Mafic unit
24LJRC0002
108
114
275.8
Felsic unit
24LJRC0003
144
150
129.6
Mafic unit
24LJRC0003
102
108
120.4
Intermediate unit
NSA
24LJRC0004
24LJRC0005
126
132
113.5
Pegmatite with a
Mafic unit
24LJRC0005
102
108
104.2
Mafic unit
24LJRC0006
120
126
227.8
Mafic unit
24LJRC0006
30
36
102.5
Regolith unit
24LJRC0006
18
24
100.8
Regolith unit
24LJRC0006
12
18
100.3
Regolith unit
24LJRC0007
126
132
205.8
Intermediate unit
24LJRC0007
108
114
124.2
Mafic unit
24LJRC0007
102
108
289.8
Mafic unit
24LJRC0008
NSA
24LJRC0009
NSA
24LJRC0010
NSA
24LJRC0011
18
24
101.8
Regolith unit
24LJRC0012
120
126
105.5
Intermediate unit
NSA
24LJRC0013
24LJRC0014
12
18
106.8
Regolith unit
NSA
24LJRC0015
24LJRC0016
120
126
104.2
24LJRC0016
90
96
100.3
Pegmatite with an
Intermediate unit
Intermediate unit
24LJRC0016
66
72
101.8
Intermediate unit
24LJRC0017
54
60
109.4
Intermediate unit
24LJRC0018
NSA
24LJRC0019
NSA
24LJRC0020
132
138
147.9
Mafic unit
24LJRC0020
120
126
217.5
Mafic unit
24LJRC0020
66
72
233.0
Mafic unit
24LJRC0021
NSA
Mafic unit
24LJRC0022
NSA
24LJRC0023
12
18
101.2
Regolith unit
24LJRC0024
120
126
129.4
Pegmatite with a
Mafic unit
ASX: BYH | bryah.com.au
8
JORC Code, 2012 Edition – Table 1 Exploration Results
Section 1 Sampling Techniques and Data
Criteria
JORC Code explanation
Commentary
Sampling
techniques
Nature and quality of sampling (e.g., cut channels, random chips, or specific
specialised industry standard measurement tools appropriate to the minerals
under investigation, such as down hole gamma sondes, or handheld XRF
instruments, etc). These examples should not be taken as limiting the broad
meaning of sampling.
Include reference to measures taken to ensure sample representivity and the
appropriate calibration of any measurement tools or systems used.
Aspects of the determination of mineralisation that are Material to the Public
Report.
In cases where ‘industry standard’ work has been done this would be relatively
simple (e.g. ‘reverse circulation drilling was used to obtain 1 m samples from which
3 kg was pulverised to produce a 30 g charge for fire assay’). In other cases, more
explanation may be required, such as where there is coarse gold that has inherent
sampling problems. Unusual commodities or mineralisation types (e.g. submarine
nodules) may warrant disclosure of detailed information.
Drill type (e.g. core, reverse circulation, open-hole hammer, rotary air blast, auger,
Bangka, sonic, etc) and details (e.g. core diameter, triple or standard tube, depth of
diamond tails, face-sampling bit or other type, whether core is oriented and if so,
by what method, etc).
Method of recording and assessing core and chip sample recoveries and results
assessed.
Measures taken to maximise sample recovery and ensure representative nature of
the samples.
Whether a relationship exists between sample recovery and grade and whether
sample bias may have occurred due to preferential loss/gain of fine/coarse
material.
Composite samples were taken from the collected sample from drilling using
a metal scoop to give a final sample of 3-5kg. These were 6 meter
composites to remove any potential smearing or contamination in sampling
between different drill rods
Samples were submitted to Intertek Genalysis for drying, crushing and
pulverising.
Sample preparation at the lab was succeeded by a four-acid digestion follow
by ICP-MS analysis for 49 elements.
Drilling
techniques
Drill sample
recovery
ASX: BYH | bryah.com.au
Drilling was undertaken using a face sampling RC drill rig. Standard
equipment was used with a 150mm hole size. 24 drill holes were completed
for 3487m
Sample recovery was monitored by the geologist on site and the driller in
charge to ensure adequate recovery.
Industry standard techniques were used to ensure that the samples were
representative and that bias was minimised through the drilling and
sampling process.
9
Criteria
JORC Code explanation
Commentary
Logging
Whether core and chip samples have been geologically and geotechnically logged
to a level of detail to support appropriate Mineral Resource estimation, mining
studies and metallurgical studies.
Whether logging is qualitative or quantitative in nature. Core (or costean, channel,
etc) photography.
The total length and percentage of the relevant intersections logged.
If core, whether cut or sawn and whether quarter, half or all core taken.
If non-core, whether riffled, tube sampled, rotary split, etc and whether sampled
wet or dry.
For all sample types, the nature, quality, and appropriateness of the sample
preparation technique.
Quality control procedures adopted for all sub-sampling stages to maximise
representivity of samples.
Measures taken to ensure that the sampling is representative of the in-situ
material collected, including for instance results for field duplicate/second-half
sampling.
Whether sample sizes are appropriate to the grain size of the material being
sampled.
The nature, quality and appropriateness of the assaying and laboratory procedures
used and whether the technique is considered partial or total.
For geophysical tools, spectrometers, handheld XRF instruments, etc, the
parameters used in determining the analysis including instrument make and model,
reading times, calibrations factors applied and their derivation, etc.
Nature of quality control procedures adopted (e.g. standards, blanks, duplicates,
external laboratory checks) and whether acceptable levels of accuracy (i.e. lack of
bias) and precision have been established.
All drill chips were geologically logged using a standardised logging template
by the geologist on site to a level sufficient for the early stage of exploration.
Sub-sampling
techniques and
sample
preparation
Quality of assay
data and
laboratory tests
Verification of
sampling and
assaying
The verification of significant intersections by either independent or alternative
company personnel.
The use of twinned holes.
Documentation of primary data, data entry procedures, data verification, data
storage (physical and electronic) protocols.
Discuss any adjustment to assay data.
ASX: BYH | bryah.com.au
Samples were collected from the extracted drill cuttings collected by drilling
assistants from the cone splitter of the RC drill rig with all attempts to keep
drill chips dry made, although not always guaranteed.
The nature, quality and appropriateness of the sample is considered to be
representative and appropriate for this stage of exploration.
Field duplicates were collected for samples at a rate of ~2 per 100 samples
collected, these showed the repeatability of the data collected.
Four acid digestion with ICP-MS finish is suitable for the total analysis of a
range of geological ores and is appropriate for analysis of lithium and a
range of other elements
Duplicate samples were submitted to the laboratory to check the
repeatability of the sampling undertaken in this program; this showed that
the data was repeatable.
No blanks or Certified Reference Material standards were submitted by
Bryah Resources. The lab undertook regular pulp checks and CRM checks.
No geophysical tools were used in quantitative determination of element
concentration.
The Competent Person has visited the site and supervised the sampling
processes in the field.
All primary data related to logging and sampling are captured using laptops
into point of capture validation LogChief templates.
All data is sent to Perth and stored in the centralised SQL Server database
with a Data Shed front end which is managed by professional database
consultants.
10
Criteria
JORC Code explanation
Commentary
Location of data
points
Accuracy and quality of surveys used to locate drill holes (collar and down-hole
surveys), trenches, mine workings and other locations used in Mineral Resource
estimation.
Specification of the grid system used.
Quality and adequacy of topographic control.
No adjustments or calibrations have been made to any assay data, apart
from resetting below detection values to half positive detection.
All sample locations have currently been surveyed with a handheld GPS by
Bryah contactors. The digital data has been loaded directly to the company
SQL Server database.
The grid system for the Lake Johnston Project is MGA_GDA1994 Zone 51.
Topographic control not relevant at this stage
Data spacing and
distribution
Sample Security
Data spacing for reporting of Exploration Results.
Whether the data spacing and distribution is sufficient to establish the degree of
geological and grade continuity appropriate for the Mineral Resource and Ore
Reserve estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
Whether the orientation of sampling achieves unbiased sampling of possible
structures and the extent to which this is known, considering the deposit type.
If the relationship between the drilling orientation and the orientation of key
mineralised structures is considered to have introduced a sampling bias, this should
be assessed and reported if material.
The measures taken to ensure sample security.
Audits or reviews
The results of any audits or reviews of sampling techniques and data.
Orientation of
data in relation
to geological
structure
RC drilling samples were collected in 6 meter composites going down hole
for all drilling undertaken in this program. This is sufficient at this stage to
gain geological and grade insights when targeting large lithium bearing
pegmatite bodies that are expected to extend over tens of meters.
The RC sampling is continuous for the entire drill hole so no “high grading” is
taking place and all of the drill hole is being represented in the assay results.
The RC sampling has not been impacted by any sampling bias.
The calico samples collected were placed in polyweave sacks by company
staff, before being transported to the relevant Perth laboratory by company
staff.
Sample security is not considered a significant risk.
The Company database has been compiled from primary data by
independent database consultants and was based on original assay data and
historical database compilations.
A regular review of the data and sampling techniques is carried out
internally.
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
ASX: BYH | bryah.com.au
11
Criteria
JORC Code explanation
Commentary
Mineral
tenement
and land
tenure
status
Type, reference name/number, location and ownership including agreements or material
issues with third parties such as joint ventures, partnerships, overriding royalties, native title
interests, historical sites, wilderness or national park and environmental settings.
The security of the tenure held at the time of reporting along with any known impediments
to obtaining a licence to operate in the area.
Exploration
done by
other
parties
Acknowledgment and appraisal of exploration by other parties.
RC drilling was undertaken on E63/2159, this tenement is 100% owned
by Bryah Resources Limited.
This tenement is located ~150km east of Hyden, adjacent to the HydenNorseman Road, near the historic Maggie-Hays and Emily-Anne mining
areas.
At the time of reporting, there are no known impediments to obtaining a
licence to operate in the area and the tenements are in good standing.
Previous historical work by other parties has been focussed on realising
the komatiite-hosted nickel and orogenic gold prospectivity of these
areas.
Work completed in the area includes various phases of surface sampling,
surface/airborne geophysical surveys, and percussion drilling.
Notable previous explorers include: LionOre Australia Ltd.; Poseiden
Nickel Ltd.; White Cliff Nickel Ltd.; Hannans Reward Ltd.; Lithium
Australia NL.; Goldfields Exploration Pty Ltd; and Lake Johnston Pty Ltd.
Geology
Deposit type, geological setting, and style of mineralisation.
Drill hole
Information
A summary of all information material to the understanding of the exploration results
including a tabulation of the following information for all Material drill holes:
• easting and northing of the drill hole collar
• elevation or RL (Reduced Level – elevation above sea level in m) of the drill hole collar
• dip and azimuth of the hole
• down hole length and interception depth
• hole length.
Exploration in the Lake Johnston Project is focussed on discovering
Lithium-Caesium-Tantalum (LCT) type pegmatite deposits analogous to
the nearby Mt Holland Lithium Mine, the Lake Medcalf Prospect (Charger
Metals), and the Mt Day / Mt Percy pegmatite swarms.
No detailed geological information is known about the sampled
pegmatites. At this stage, they are inferred to be geochemically similar to
other LCT pegmatites
These details can be found in the preceding table in this announcement.
If the exclusion of this information is justified on the basis that the information is not
Material and this exclusion does not detract from the understanding of the report, the
Competent Person should clearly explain why this is the case.
ASX: BYH | bryah.com.au
12
Criteria
JORC Code explanation
Commentary
Data
aggregation
methods
In reporting Exploration Results, weighting averaging techniques, maximum and/or minimum
grade truncations (e.g., cutting of high grades) and cut-off grades are usually Material and
should be stated.
Where aggregate intercepts incorporate short lengths of high-grade results and longer
lengths of low-grade results, the procedure used for such aggregation should be stated and
some typical examples of such aggregations should be shown in detail.
The assumptions used for any reporting of metal equivalent values should be clearly stated.
These relationships are particularly important in the reporting of Exploration Results.
If the geometry of the mineralisation with respect to the drill hole angle is known, its nature
should be reported.
If it is not known and only the down hole lengths are reported, there should be a clear
statement to this effect (e.g., ‘down hole length, true width not known’).
No high-grade cuts have been applied to the reporting of exploration
results.
A low grade cut off of 75ppm Li2O has been used for listing the peak
intercepts in the assays from RC drilling.
No metal equivalent values have been used.
Relationship
between
mineralisati
on widths
and
intercept
lengths
Diagrams
Balanced
reporting
Other
substantive
exploration
data
Further
work
Appropriate maps and sections (with scales) and tabulations of intercepts should be included
for any significant discovery being reported These should include, but not be limited to a plan
view of drill hole collar locations and appropriate sectional views.
Where comprehensive reporting of all Exploration Results is not practicable, representative
reporting of both low and high grades and/or widths should be practiced to avoid misleading
reporting of Exploration Results.
Other exploration data, if meaningful and material, should be reported including (but not
limited to): geological observations; geophysical survey results; geochemical survey results;
bulk samples – size and method of treatment; metallurgical test results; bulk density,
groundwater, geotechnical and rock characteristics; potential deleterious or contaminating
substances.
The nature and scale of planned further work (e.g. tests for lateral extensions or depth
extensions or large-scale step-out drilling).
Diagrams clearly highlighting the areas of possible extensions, including the main geological
interpretations and future drilling areas, provided this information is not commercially
sensitive.
ASX: BYH | bryah.com.au
Drilling was completed with all drill holes oriented to true east (90°) with
a dip of -60° as the spatial arrangement of the initial soil anomalism
suggested the modelled pegmatite target may be oriented N-S and
dipping to the west.
The orientation of any mineralised body is unknown and as such reported
lengths are down hole lengths, true widths are unknown.
See attached figures within this announcement.
The reporting of exploration results within this announcement is
appropriate for this stage of exploration. This includes the reporting of
lithium as well as other ‘pathfinder’ elements.
Geochemical assay for all selected elements, for all samples have been
provided.
Refer to Appendix 1 of this announcement.
No other exploration data available.
Further work is discussed in the main body of text.
Work proposed will be undertaken over the subsequent 12 months,
subject to project priorities and staffing availability.
13
Share your feedback
Discover